INSTALLATION IN BUILDING WITH SEVERAL POINTS OF ENTRY WITH CON-CIERGE UNITCONVENTIONAL 4+N SYSTEMStandard wiring diagram for door entry installations in buildings with several points of entry, controlled by a concierge.RemarksDetermining the main entrance panelOne of the entrance panels must be configured as the main panel (audio unit with J1 jumper installed). The panels of the otherpoints of entry must be configured as secondary panels (remove the J1 jumper from audio units).SINGLE-WIRED DIAGRAM5 5SECTION TABLEAWGUp to 50 metres1 mm 21.1 mm 17Up to 25 metres(3)12340.5 mm 2 0.8 mm 20Up to 100 metres2 0.25 mm 0.6 mm 222 0.5 mm 0.8 mm 202 0.75 mm 1.0 mm 182 1 mm 1.1 mm 17TEL-001LAST FLOOR5 5TEL-001(1) Use separate cable hose(2) Max. 12 Vac, 800 mA(3) Section according to the numberof telephones in the dwellingTEL-001GROUND FLOORTEL-001ALA-040 (230 V )ALA-040 (230 V )ALA-040 (230 V )4+N230 VVNEXTPOINT OF ENTRY230 VV2POINT OFENTRY 2230 VV2POINT OFENTRY 1CONCIERGE2230 VV8+N(1)8+N(1)8+N(1)2MAN-430+MPD-009+CMO-0102MAN-430+MPD-009+CMO-010COA-010+CMO-010MAN-460+MPD-009+CMO-010+CEM-001ABR-001(2)ABR-001(2)206