1 2 34 5 67 8 9C 01 2 34 5 67 8 9C 01 2 34 5 67 8 9C 0STANDARD ELECTRONIC DOOR ENTRY INSTALLATION IN DETACHED HOUSEWITH INTERNAL COMMUNICATION BETWEEN TELEPHONESCONVENTIONAL SYSTEMStandard wiring diagram for electronic door entry system with electronic call in detached houses with a single point of entry wherethe possibility of internal communication is required between a number of telephones in the house. Characteristics of the internalcommunication: electronic call and and internal communication channel, with complete confidentiality.RemarksAssigning a extension number to each telephoneA different extension number is assigned to each telephone with internal communication. (See in chapter 5 the adjustment instructionsof telephone for internal communication).SINGLE-WIRED DIAGRAMTIN-0015TIN-0015TIN-001112222SECTION TABLEAWGALA-040 (230 V )5GCI-0011 mm 2Up to 50 metresUp to 25 metres1.1 mm 17230 V V(1)ABR-001(2)22POINTOF ENTRYMAN-410+MPS-001+CMO-002230 V I2 I10.5 mm 2 0.8 mm 20Up to 100 metres1 mm 2 1.1 mm 172 0.25 mm 0.6 mm 2221 0.25 mm 0.6 mm 2222 0.5 mm 0.8 mm 20(3) 32 0.75 mm 1.0 mm 1824 1 mm 1.1 mm 17(1) Use separate cable hose(2) Max. 12 Vac, 800 mA(3) Section according to the numberof telephones in the dwelling224