ACTIVATING THE STAIRS LIGHTING WHEN THE DOOR IS OPENEDUseIt is possible to activate the stairs lighting of the building at the same time that an alternating voltage is sent to the electric lock.This can be useful when, for safety reasons, it is desirable to light up the hall or doorway of the building once the visitor has beenallowed to enter.OperationWhen the lock-release button of the telephone or monitor is pressed, the audio unit detects the closing of the lock-release circuit(terminals 1, 2). The audio unit then sends an AC voltage (terminals 11, 12) to the electric lock, allowing the entry door to be opened,and to the ASC-050 ( and Ctrl2 terminals), allowing the light switch circuit to be closed.WIRED DIAGRAMASC-050ASC-050cod. 97300215A / 250V~S2 S52 5Ctrl16Ctrl2 C NO NC19J1Made in SpainV~ 910 11 12 13 14 15 1 2 3 4 716 17 18Max. 250 Vac/5ALIGHTIN STAIRSABR-001SECTION TABLEAWGUp to 25 metres0.5 mm 2 0.8 mm 20ACTIVATING A LIGHT, BELL OR SIREN WHEN A CALL IS RECEIVED IN THEDWELLINGUseIt is possible to activate a light, bell or siren (up to 250Vac and 5A) when a call is received in the dwelling. This can be useful indwellings where, for example, the user has hearing problems, or in installations in noisy environments, such as factories.283