INSTALLATION IN BUILDING WITH SEVERAL POINTS OF ENTRY. CONFIDENTIALITYFEATURE.CONVENTIONAL 4+N SYSTEMStandard wiring diagram for door entry installations with confidentiality feature in buildings with several points of entry.RemarksDetermining the main entrance panelOne of the entrance panels must be configured as the main panel (audio unit with J1 jumper installed). The panels of the otherpoints of entry must be configured as secondary panels (remove the J1 jumper from audio units).SINGLE-WIRED DIAGRAM55SECTION TABLEAWGTES-001LAST FLOORTES-001Up to 50 metres1 mm 2 1.1 mm 17Up to 25 metres0.5 mm 20.8 mm 20Up to 100 metres5 5(3)12342 0.25 mm 0.6 mm 222 0.5 mm 0.8 mm 202 0.75 mm 1.0 mm 182 1 mm 1.1 mm 17TES-001GROUND FLOORTES-001(1) Use separate cable hose(2) Max. 12 Vac, 800 mA(3) Section according to the numberof telephones in the dwellingALA-040 (230 V )4+NALA-040 (230 V )230 V V(1)22POINT OFENTRY 1MAN-441+MPD-004+CMO-0046+NMAN-441+MPD-004+CMO-004POINT OFENTRY 222(1)230 V V6+NNEXTPOINT OF ENTRY230 VVABR-001(2)ABR-001(2)218