Made in SpainCALL ADAPTER ACCESSORIES40 mm88 mmCod.9730005AAL-001IN OUTV V 2 7 8 16 1721 mmCod. 9730005AAL-001CALL ADAPTER ACCESSORYDevice which complements the GRF-203 electronic audio unit for installations with several points ofentry with buzzing call. Capable of converting an electronic call to a buzzing call.Of suitable dimensions for fixing inside the flush-mounted box or surface wall-mounted box of theentrance panel.Description of terminals and voltages:Note: The voltages shown are reference values provided for the testing of the equipment and are intended for use exclusivelywith ALCAD audio units. Do not use the terminals of the equipment to supply power to additional devices without previously consultingthe manufacturer.TERMINALS AT REST WORKINGAAL-001Cod.9730005IN OUTV V 2 7 8 16 17Made in SpainV,7 , 28 , 216 , 217 , 2Power supply voltageCommon push button terminal(electronic call)Common push button terminal(buzzing call)EstateSeveral points of entryIN , V12 VOUT , V12 V7, 2 14.5 V 10.5 Vpp8, 26 V 12 V16, 2 0 V 4 VELECTRONIC MODULES17, 2 0 V 8 VElements necessary for carrying out certain installations of electronic door entry or video door entry systems.ELECTRONIC MODULES FOR INTERNAL COMMUNICATION INSTALLATIONS90 mm175 mm230 V I2 I11160 mmCod. 9650001CGI-001CONTROL EQUIPMENT FOR INSTALLATIONS WITH INTERNAL COMMUNI-CATIONUnit responsible for managing internal communication system between the TIN-001 telephonesfor internal communication. Equipped with a LED to indicate that the unit is in use (1). If ashort-circuit occurs in the internal communication BUS, the LED will blink continuously, ceasing todo so when the short-circuit has been eliminated. 10-unit DIN rail format for wall or rail mounting.Only one unit is required for each installation with internal communication (for up to 16 telephonesfor internal communication).The electronic circuit is protected against short-circuits.Operating temperature -10 to + 55 °CDescription of terminals and voltages:Note: The voltages shown are reference values provided for the testing of the equipment. Do not use the terminals of the equipmentto supply power to additional devices without previously consulting the manufacturer.230 VI1, I2Mains voltageInternal communication BUSTERMINALS INACTIVE AT REST WORKING230 V230 V ±10% 50/60 Hz230 V I2 I1I1 , I210 - 12 V87

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!