EXTENSION OF THE INSTALLATION WITH CALL EXTENSIONSDOOR ENTRY INSTALLATIONSUseIt is possible to extend the installation in a dwelling by adding call extensions, to a maximum of 3 devices per dwelling (wheredevices are call extensions and telephones). Each call extension will be able to receive calls.OperationThe electronic call signal is shared by the call extensions and telephones. By respecting the sections indicated in this technicalmanual, it is possible to install up to 3 devices (where devices are telephones and call extensions).All the devices receive the call simultaneously.DOOR ENTRY INSTALLATIONS. ELECTRONIC CALLSINGLE-WIRED DIAGRAM(1)23SECTION TABLEAWGUp to 100 metres2 0.5 mm 0.8 mm 202 0.75 mm 1.0 mm 18(1) Section according to the numberof devices in the dwellingAAL-2002 5TEL-001WIRED DIAGRAM(1)23SECTION TABLEAWGUp to 100 metres2 0.5 mm 0.8 mm 202 0.75 mm 1.0 mm 18(1) Section according to the numberof devices in the dwelling2 51 2 3 4 5AAL-200TEL-001267