12.07.2015 Views

Conventional Systems Technical Manual - Alcad

Conventional Systems Technical Manual - Alcad

Conventional Systems Technical Manual - Alcad

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

INSTALLATION IN BUILDING WITH SEVERAL POINTS OF ENTRYHOUSING ESTATE WITH SEVERAL BUILDINGS. 1 EXTERNAL POINT OF ENTRY(GATE)Nothing works.Check the mains voltage in the power supply. Check that thevoltage between V~, of the power supply is 12 ± 10% Vac.Check wether there is a short circuit and fix it. Disconnect thepower supply for 1 minute and then connect it up again.If it still doesn't work, disconnect all the power supplyV~, terminals, and check that the voltage between V~, is12 ± 10% Vac, if it is not, then there may be something wrongwith the power supply.The card holders don't light up.Check that the voltage between V~, of the power supply is12 ± 10% Vac.Check that the voltage between 9,10 in the audiounit, with the lighting push button activated, is 12 ± 10%Vac.Check wether the lamp has burnt out.The lighting push button pilot does not light up.Check that the voltage between the V~, of the audio unit is12 ± 10% Vac. If the voltage is correct, there may be somethingwrong with the audio unit.The call tone doesn’t ring on any telephone.Check that the voltage between 7,2 in the audio unit, withoutpressing the push button, is 9 ± 10% Vdc. Check the connectionbetween 7 in the audio unit and the push buttons. Check connection2 from the audio unit to the telephones. If you cannot findthe fault, there may be something wrong with the audio unit.The call tone doesn’t ring in a telephone.Check that the telephone is not off the hook. Check connections5,2 from the telephone to the entrance panel. Check the push-buttonconnection on the entrance panel. If you cannot find the fault,there may be something wrong with telephone or the panel pushbutton.You cannot hear the call confirmation on the entrancepanel.Check that you can hear the telephones on the entrance panel.Check that the call tone rings on the telephones. If you cannotfind the fault, there may be something wrong with the audio unit.You cannot hear any telephones from the entrancepanel.Check connections 3,2 from the audio unit to all the telephones.Check the volume control on the panel. If you cannot findthe fault, there may be something wrong with the audio unit.You cannot hear a telephone from the entrancepanel.Check connections 3,2 from the telephone to the audio unit. Ifyou cannot find the fault, there may be something wrong with thetelephone.You cannot hear an entrance panel on any telephone.Check connections 4,2 from the audio unit to all the telephones.Check the volume control on the telephones on theentrance panel. If you cannot find the fault, there may be somethingwrong with the audio unit.You cannot hear the entrance panel on a telephone.Check connections 4,2 from the telephone to the audio unit.If you cannot find the fault, there may be something wrong withthe telephone.You can hear whistling in the panel. The soundproduces feedback.Lower the sound level using the volume control on the audiounit.The electric lock doesn’t work.Check that the voltage between 1,2 in the audio unit, withoutpressing the lock release button, is 5 ± 10% Vdc. Check thatthe voltage between 11,12 in the audio unit, when you pressthe lock release button, is 12 ± 10% Vac. If you cannot findthe fault, the electric lock may be broken.When you call one of the panels the rest of thepanels in the system are not disabled.Make certain that connectors 17,18 on the panels are connectedup. If this is the case, make certain that connectors16,18 are connected up. Check that the voltage between 17,2in each one of the audio unit is 8 ± 10% Vdc and the voltagebetween 16,18 is 4 ± 10% Vdc when you press the push buttonon one of the panels. If you cannot find the fault, there maybe something wrong with the audio unit.297

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!