7. MAINTENANCE AND TROUBLESHOOTINGErrorCodeType Message CauseLocationof error9509 Warning Access fault. Cannot access SIM (checkswhen card is entered, noticedisplays for 1 second).9603 Warning PHY IC fault. Device error (cannot accessPHY IC).9604 Warning CODEC IC fault. Device error (cannot accessCODEC IC).9605 Warning LCD fault. Device error (cannot accessLCD).SIMHandsetHandsetHandset7.7 How to Restore Default Settings (Initialize)You can restore default settings for the handset and Web software. Data is deletedwhen default settings are restored. Data cannot be recovered so restore default settingswith caution.7.7.1 Handset initializationThere are two methods to restore the handset to default settings:Refer to the following table for detailed guide on what settings are included in the reset:Item Except con. All settings[Web top] menu: [1 InputURL] -> [Input History][Web top] menu: [2 Favorites][Web top] menu: Cachedweb page data[Web top] menu: [4 Settings][SMS] menu: All messagesin message boxNoNoNoYesNoNoNoNoYesNo[SMS] menu: [6 Settings] No YesSystem messages No NoAll data in Contacts No No[Settings] menu: [1 Basic] Yes Yes[Settings] menu: [2 Network]NoYes[Settings] menu: [3 SIP] No YesOperation Password No Yes7-11