<strong>VFD</strong>-F SeriesSetting FunctionsDescriptions21 Low voltage detection The corresponding output will be closed whenthe DC Bus voltage drops below our threshold.The keypad will display “Lu”.22 Operation Mode indication The corresponding output will be closed whenthe AC drives “Operation Command” iscontrolled by the external terminals.23 Fault Indication The corresponding output will be closed whenAC drive has experienced a fault.24 Master Frequency Attained 1 The corresponding output will be closed whenthe AC drives output frequency exceeds(Pr.03-08) Master Frequency Attained 1.25 Master Frequency Attained 2 The corresponding output will be closed whenthe AC drives output frequency exceeds(Pr.03-09) Master Frequency Attained 2.26 Over Temperature indication The corresponding output will be closed whenthe AC drive temperature exceeds its rating.27 Drive Ready The corresponding output will be closed thewhen the AC drive is ready and has no faults.28 External Emergency Stop (EF1) The corresponding output will be closed whenmulti-function input terminals (Pr.04-00 to04-07) are set to emergency stop and thenactivated.29 Software brake output The corresponding output will be closed whenthe AC drives DC bus voltage exceeds(Pr.08-19) the brake level.30 OL or OL1 overload warning The corresponding output will be closed uponan overload (OL or OL1) fault.31 Dwell indication (sleep) The corresponding output will be closed whenthe AC drive is in a Dwell status (Pr.11-07).32 Low current indication The corresponding output will be closed whenthe AC drives output current is lower than theLow Current setting (Pr.06-08).33 PID feedback error indication The corresponding output will be closed whenthe PID feedback signal has an error.34 PLC Program RunningThe Output will be activated when PLCProgram is running.35 PLC Program Step CompletedThe Output will be activated for 0.5 sec wheneach multi-step speed is attained.36 PLC Program CompletedThe output will be activated for 0.5 sec whenthe PLC program cycle has completedThe output will be activated when PLC37 PLC Operation Pausedoperation is paused. The <strong>VFD</strong>-F has two form C relays (multi-function output 1 and 2). There is an optionalExternal Relay Card with 6 NO contact relays (multi-function outputs 3-8).5-16DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!