<strong>VFD</strong>-F Series Unsuitable setting value may cause over compensation.07 - 05 Rated Slip Frequency of Motor Factory Setting: 0.00Settings 0.00~20.00Hz Unit: 0.01 This parameter is to set rated slip of loaded motor. Users need to input rated rotation speedaccording to nameplate of loaded motor. If rated frequency of motor is 60Hz, number ofmotor poles is 4 and rated rotation speed of motor is 1650rpm. The rated slip frequency ofmotor is 60Hz-(1650rpm X 4/120) = 5Hz. This parameter has relation with 07-04 slip compensation. To have the best slipcompensation, this parameter must be set correctly. Incorrect setting may cause abovefunctions disable and even damage the motor and AC drive.07 - 06 Auto Torque Compensation Gain Factory Setting: 0.0Settings 0.0~10.0 Unit: 0.1 This parameter is to set auto torque compensation gain. When motor loading is high, a part of output frequency of AC drive will be absorbed byimpedance of stator winding to make voltage of exciting inductance of motor is not enough.Therefore, the short of gap magnet field will make a high output current but low outputtorque. Auto torque compensation gain could adjust output voltage automatically accordingto loading to maintain in a fixed gap magnet of the motor to get the best running situation. If the setting of compensation gain is too great, over-exciting magnet will cause thefollowing situation: output current of AC drive is too great, motor is over-heating orprotection function occurs.07 - 07 Torque Compensation Gain by Manual Operation Factory Setting: 0.0Settings 0.0~10.0 Unit: 1.0 This parameter determines torque compensation gain by manual operation. Torque compensation gain by manual operation won’t refer to the loading situation andadds compensation voltage on the setting V/f curve. Basically, it just changes V/f curve. Itcould be reached by adjusting V/f curve.07 - 08 Calculate Total Running Time of the Motor (Min) Factory Setting: 00Settings 00 to 1439 Min Unit: 107 - 09 Calculate Total Running Time of the Motor (Day) Factory Setting: 00Settings 00 to 65535 Day Unit: 1 This parameter could display running time of the motor.5-38DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!