<strong>VFD</strong>-F SeriesExample 3 (Pr.05-15 = 3) Execute one cycle step by step:The example below shows how the PLC can perform one cycle at a time, within in a completecycle. Each step will use the accel/decel times in Pr.01-09 to Pr.01-16. It should be noticed thatthe time each step spends at its intended frequency is diminished, due to the time spent duringaccel/decel.FrequencyPLC operation execution one cycle step by step05-0205-0305-01Program operationcommand OFFProgram operationindication OFF05-001 2 3 405-17 t05-18 t05-19 t05-20ONON ON ON ONTimeStep operationindication OFF05 - 16 PLC Forward/Reverse Motion Factory Setting: 00Settings 00 to 32767 This parameter controls the direction of motion for the Multi-Step Speeds Pr.05-00 toPr.05-14 during PLC mode. All other direction commands are invalid during the PLC mode.Note:The equivalent 15-bit number is used to program the forward/reverse motion for each ofthe 15 speed steps. The binary notation for the 15-bit number must be translated intodecimal notation and then entered.5-26DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED