21.07.2015 Views

M16C User Manual.pdf

M16C User Manual.pdf

M16C User Manual.pdf

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Power controlMitsubishi microcomputers<strong>M16C</strong> / 62 GroupSINGLE-CHIP 16-BIT CMOS MICROCOMPUTERTransition of stop mode, wait modeResetAll oscillators stoppedCM10 = “1”Stop modeInterruptInterruptAll oscillators stoppedCM10 = “1”Stop modeMedium-speed mode(divided-by-8 mode)High-speed/mediumspeedmodeWAITinstructionInterruptWAITinstructionInterruptCPU operation stoppedWait modeCPU operation stoppedWait modeAll oscillators stoppedStop modeCM10 = “1”InterruptLow-speed/low powerdissipation modeWAITinstructionInterruptCPU operation stoppedWait modeNormal mode(Refer to the following for the transition of normal mode.)Transition of normal modeCM06 = “1”Main clock is oscillatingSub clock is oscillatingHigh-speed modeBCLK : f(XIN)CM07 = “0” CM06 = “0”CM17 = “0” CM16 = “0”Medium-speed mode(divided-by-4 mode)BCLK : f(XIN)/4CM07 = “0” CM06 = “0”CM17 = “1” CM16 = “0”Main clock is oscillatingSub clock is stoppedMedium-speed mode(divided-by-8 mode)BCLK : f(XIN)/8CM07 = “0” CM06 = “1”CM04 = “0”CM04 = “1”(Notes 1, 3)Medium-speed mode(divided-by-2 mode)BCLK : f(XIN)/2CM07 = “0” CM06 = “0”CM17 = “0” CM16 = “1”Medium-speed mode(divided-by-16 mode)BCLK : f(XIN)/16CM07 = “0” CM06 = “0”CM17 = “1” CM16 = “1”Medium-speed mode(divided-by-8 mode)BCLK : f(XIN)/8CM07 = “0”CM06 = “1”CM07 = “0” (Note 1)CM06 = “1”CM04 = “0”CM07 = “0”(Note 1, 3)CM07 = “1”(Note 2)Main clock is oscillatingSub clock is oscillatingLow-speed modeBCLK : f(XCIN)CM07 = “1”CM05 = “0” CM05 = “1”CM04 = “0” Main clock is oscillatingSub clock is stoppedCM04 = “1”Medium-speed modeHigh-speed mode (divided-by-2 mode)BCLK : f(XIN)CM07 = “0” CM06 = “0”CM17 = “0” CM16 = “0”BCLK : f(XIN)/2CM07 = “0” CM06 = “0”CM17 = “0” CM16 = “1”CM07 = “1” (Note 2)CM05 = “1”Main clock is stoppedSub clock is oscillatingLow power dissipation modeBCLK : f(XCIN)CM07 = “1”CM06 = “0”(Notes 1,3)Medium-speed mode(divided-by-4 mode)BCLK : f(XIN)/4CM07 = “0” CM06 = “0”CM17 = “1” CM16 = “0”Medium-speed mode(divided-by-16 mode)BCLK : f(XIN)/16CM07 = “0” CM06 = “0”CM17 = “1” CM16 = “1”CM07 = “0” (Note 1)CM06 = “0” (Note 3)CM04 = “1”Note 1: Switch clock after oscillation of main clock is sufficiently stable.Note 2: Switch clock after oscillation of sub clock is sufficiently stable.Note 3: Change CM06 after changing CM17 and CM16.Note 4: Transit in accordance with arrow.Figure 1.13.5. State transition diagram of Power control mode49

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!