Electrical SpecificationsEnglishInput (RUN) CoilOrder No. <strong>3RW34</strong>..0DC2. ..0DC3. ..0DC4.Coil Voltage 24 V DC 115 V AC 230 V ACIsolation Voltage, V AC 1500 1500 1500Input Current, mA 10 10 10On Voltage, volts min. 17 V DC 85 V AC 170 V ACOn Current, mA min. 6 6 6Off Voltage, volts max. 8 V DC 40 V AC 80 V ACOff Current, mA max. 3 3 3Input Impedance, ohms (typical) 5 k 12 k 27 kTable 6 : Input (RUN) CoilUser Outputs Rating Outputs are rated 0.5 A maximum at 24 V DC, and 1.0 A at115 V AC and 230 V AC.User Output for 115 V AC and230 V AC versionUser Output for 24 V DCversionISOL Logic to PowerRatingOn Voltage DropOn CurrentOff Leakage CurrentISOL Logic to PowerRatingOn Voltage DropOff Leakage Current1500 V AC10 A Make1A Break1 A Continuous at 115 V AC / 230 V AC1.2 V AC (typical)25 mA (minimum)2 mA (typical)1500 V AC1.5 A Make0.5 A Break0.5 A Continuous at 24 V1.6 V DC (typical)2 mA (typical)Solid-State Outputs M (RUN) When soft starter is operating, the RUN contact is closed.Um = 100 %FAULTWhen motor is running at 100 % of line voltage (after starting iscomplete), the Um contact is closed.The FAULT contact responds either to an EEPROM error or to ashort-circuited thyristor, depending on the setting of switchSW1-4.(Refer to Section 7.1 re SW1-4 settings. Reset fault simply bygiving a new start signal.)RecommendedFuse Type*Two levels of short circuit protection can be provided by the user:1. Type 1 protection is available where the short circuit protective device protects the wiring and theintegrity enclosure. The soft starter will probably damage and require replacement or repair beforebeing re-energized. Circuit breakers and motor circuit protectors provide this type of protection.2. Type 2 protection is available where the short circuit protective device protects both the wiring and thesoft starter. The soft starter should not require repair before re-energizing after the short circuit has beencleared. Fuses of an KR-1 type or HRC-1 type sized in accordance with the NEC/CEC code or SITORsemiconductor type fuses provide this kind of protection.* For a complete listing of <strong>Siemens</strong> SITOR fuses, see Appendix A.24 3ZX1012-0RW34-1AN1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!