20.03.2013 Views

Eurobodalla Integrated Water Cycle Management Strategy

Eurobodalla Integrated Water Cycle Management Strategy

Eurobodalla Integrated Water Cycle Management Strategy

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

100<br />

<strong>Eurobodalla</strong> <strong>Integrated</strong> <strong>Water</strong> <strong>Cycle</strong> <strong>Management</strong> <strong>Strategy</strong><br />

A southern dam (5 600 ML).<br />

<strong>Integrated</strong> Option 1: Enhance Existing Supply Scheme Plus Southern Dam and<br />

Comprehensive Demand <strong>Management</strong><br />

This option consists of:<br />

Immediate and short term measures as discussion in section 8.3.3. The initial<br />

capacity of northern and southern filtration plants would be 26 ML/d and 10 ML/d<br />

respectively.<br />

A comprehensive demand management comprising:<br />

− Community education targeting outdoor irrigation<br />

− A active program to retrofit water efficient fittings and equipment, such as<br />

shower roses and aerated taps<br />

− Pricing adjustments<br />

− Active system leak detection and repair<br />

A southern dam (1 500 ML).<br />

<strong>Integrated</strong> Option 2: Enhanced Existing Supply Scheme Plus Southern Dam,<br />

Comprehensive Demand <strong>Management</strong> and Rainwater Tanks<br />

This option consists of:<br />

Immediate and short term measures as discussion in section 8.3.3. The initial<br />

capacity of northern and southern filtration plants would be 24.5 ML/d and 9.5 ML/d<br />

respectively.<br />

A comprehensive demand management comprising:<br />

− Community education targeting outdoor irrigation<br />

− A active program to retrofit water efficient fittings and equipment, such as<br />

shower roses and aerated taps<br />

− Pricing adjustments<br />

− Active system leak detection and repair<br />

10 kL rainwater tank for all new developments with water used for garden watering,<br />

toilet flushing and washing machines, and a retrofit of 10 kL rainwater tanks in 20%<br />

of existing houses<br />

A southern dam (900 ML).<br />

<strong>Integrated</strong> Option 3: Option 2 plus Reticulated <strong>Water</strong> to High Priority Villages<br />

This option consists of:<br />

Immediate and short term measures as discussion in section 8.3.3. The initial<br />

capacity of northern and southern filtration plants would be 24.5 ML/d and 9.5 ML/d<br />

respectively.