2.1.6 Hybrid connectors<br />

Figure 6: Hybrid connectors<br />

<strong>PROFINET</strong> cable assembly work<br />

Hybrid connectors use the same connector <strong>for</strong> the power supply of the <strong>PROFINET</strong><br />

nodes <strong>and</strong> <strong>for</strong> the connection of the <strong>PROFINET</strong> cable. This reduces the installation<br />

work. <strong>Installation</strong> can be simplified significantly by using ready-made cables that are<br />

available from the cable manufacturers in various lengths. Where connectors have<br />

to be assembled on site due to deviating cable lengths or repair work, the<br />

manufacturer’s instructions shall be observed. The contacts of hybrid connectors<br />

are usually crimped. Crimping tools are provided by the connector manufacturers.<br />

Use only crimping tools specified by the manufacturer of the connector. Correctly<br />

crimped connections are m<strong>and</strong>atory <strong>for</strong> a permanent, high-quality connection.<br />