4.7.4.4 Stopping distances and stopping times for STOP 1, axis 3<br />
Fig. 4-32: Stopping distances for STOP 1, axis 3<br />
Fig. 4-33: Stopping times for STOP 1, axis 3<br />
4.7.5 Stopping distances and times, <strong>KR</strong> 180 R2500 <strong>extra</strong> C<br />
4.7.5.1 Stopping distances and stopping times for STOP 0, axis 1 to axis 3<br />
Issued: 29.11.2012 Version: Spez <strong>KR</strong> <strong>QUANTEC</strong> <strong>extra</strong> V4 en (PDF)<br />
4 Technical data<br />
The table shows the stopping distances and stopping times after a STOP 0<br />
(category 0 stop) is triggered. The values refer to the following configuration:<br />
Extension l = 100%<br />
Program override POV = 100%<br />
Mass m = maximum load (rated load + supplementary load on arm)<br />
Stopping distance (°) Stopping time (s)<br />
Axis 1 81.65 1.22<br />
Axis 2 50.09 0.693<br />
Axis 3 50.83 0.61<br />
51 / 127