27.06.2013 Views

Modeles 4370 UR1800 Recorder Instruction Manual

Modeles 4370 UR1800 Recorder Instruction Manual

Modeles 4370 UR1800 Recorder Instruction Manual

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Display and functions do not work properly.<br />

Is the input free of noise?<br />

YES<br />

Contact your nearest Sales &<br />

Service center<br />

Panel key does not work properly.<br />

Is the key-lock unlocked?<br />

YES<br />

Contact your nearest Sales &<br />

Service center<br />

NO<br />

NO<br />

Ground the recorder properly.<br />

Use shielded wire for input and communication.<br />

Insert an isolated transformer into the power line.<br />

Insert a power line filter into the power line.<br />

In case a reactive road is used as an alarm output<br />

line, use a surge suppressor in the alarm line.<br />

Separate the input & communication wires from<br />

the noise generating wire.<br />

Insert the key (see 5.4).<br />

Set the key-lock to NOT USE in the<br />

SET UP Mode (see 9.10).<br />

12 - 4 IM 4H3B1-01E

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!