YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Display and functions do not work properly.<br />
Is the input free of noise?<br />
YES<br />
Contact your nearest Sales &<br />
Service center<br />
Panel key does not work properly.<br />
Is the key-lock unlocked?<br />
YES<br />
Contact your nearest Sales &<br />
Service center<br />
NO<br />
NO<br />
Ground the recorder properly.<br />
Use shielded wire for input and communication.<br />
Insert an isolated transformer into the power line.<br />
Insert a power line filter into the power line.<br />
In case a reactive road is used as an alarm output<br />
line, use a surge suppressor in the alarm line.<br />
Separate the input & communication wires from<br />
the noise generating wire.<br />
Insert the key (see 5.4).<br />
Set the key-lock to NOT USE in the<br />
SET UP Mode (see 9.10).<br />