1.2 Summary of Functions<br />

This paragraph describes a summary of the main functions, together with a recording<br />

example.<br />

RECORDING<br />

Trend: records in a way that the dots do not overlap (dot model only)<br />

Zone: records on different bands (zones) for individual channels<br />

Partial: expands part of the recording range for detailed examination<br />

POC: Pen Offset Compensation: removes the time-axis offset between pens (pen model only)<br />

PRINTOUT<br />

Channel printout: contains channel No. besides analog recording (dot model only)<br />

List printout: contains date, time, chart speed (1 & 2), channel No. or tag, range, span values, scale<br />

values, partial values and contents of messages (for example, see 5.3.4)<br />

<strong>Manual</strong> printout: contains date and time, channel No., type of alarm, latest measured values, units (for all<br />

channels)<br />

Alarm printout: contains channel or tag No., type of alarm, level, mark ( for occurence, for recover;<br />

in case of the dot model, red and blue respectively) and alarm ON/OFF-time<br />

Periodic printout: contains date & time, tag or channel No., POC ON mark ( ; for pen model only), unit,<br />

scale markings (may not be printed while alarm occurs), chart speed, measured values<br />

and recording color (for pen model) and time tick (for dot model)<br />

Message printout: contains time and message<br />

Recording start printout: contains time when recording starts<br />

Chart speed change: contains time and new chart speed<br />

SET UP List printout: contains initial settings concerning analog recording, digital printing, alarms, burnout,<br />

RJC and options (for example, see 5.3.5)<br />

NOTE The alarm, channel (for dot model), periodic, message, recording start and chart speed<br />

change printout depend on the chart speed. The size of the characters varies depending<br />

on the chart speed.<br />

Time tick (–) always corresponding to pen No.1 when POC is OFF.<br />

Corresponding to all pens when POC is ON.<br />

Figure 1.1 Recording Example for Pen Model<br />

<strong>Manual</strong> printout<br />

Time tick cancel mark (!)<br />

appears when chart feed/speed<br />

has been changed during<br />

periodic printout<br />

POC ON mark<br />

Periodic printout<br />

Scale printout an Recording<br />

color<br />

Chart speed change printout<br />

Message printout<br />

Alarm printout<br />

Note: When an asterisk appears<br />

( ), the memory buffer is full<br />

and some data will not be printed.<br />

This asterisk may appear in the<br />

alarm printout, message printout,<br />

recording start time printout and<br />

the chart speed change printout.<br />

Recording start time<br />

1 - 2 IM 4H3B1-01E