4.2 Display<br />

3<br />

2<br />

3<br />

2<br />

1<br />

2<br />

3<br />

4<br />

RCD<br />

POC<br />

SET<br />

AUTO<br />

MAN<br />

CLK<br />

Figure4.3a Display (4 pen model)<br />

RCD<br />

POC<br />

SET<br />

1<br />

AUTO<br />

MAN<br />

CLK<br />

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24<br />

Figure 4.3b Display (dot model)<br />

1 5 × 7 dot matrix (20 characters)<br />

Used for data display, clock display, monitor display and setting display (see also 5.3.8).<br />

Data display: Channel No. or tag, type of alarm, measured data, units<br />

Clock display: (year, month, day) and (hour, minutes, seconds)<br />

Monitor display: Operating conditions of IC Memory Card and TLOG function<br />

Setting display: Every parameter can be set by interactive display.<br />

2 Bargraph<br />

Measured values of each channel will be displayed with 1% resolution (analog display).<br />

The alarm set points will also be displayed. The colors of the bargraph correspond to<br />

the colors of the pens. Two ways of display can be selected:<br />

Left-referenced (%) bargraph Center-zero bargraph<br />

(center of the recording span is reference<br />

and the deviation is displayed as a bargraph)<br />

1<br />

2<br />

The squares underneath the bargraph show the occurrence of an alarm in the<br />

corresponding channel. They illuminate/flash in the same way as the ALM-indicator.<br />

3 Status indicators<br />

RCD: Illuminated when recording is in progress.<br />

POC: Illuminated when Pen Offset Compensation is being used (only for pen model).<br />

SET: Illuminated when you are working in the SET Mode.<br />

AUTO: Illuminated when the AUTO display is used.<br />

MAN: Illuminated when the <strong>Manual</strong> display is used.<br />

CLK: Illuminated when the Clock display is used.<br />

ALM: This VFD will flash or illuminate when an alarm occurs.<br />

Hold-mode: If the ACK-key is pressed, the flashing will stop and the VFD<br />

will illuminate. After the alarm stops, the VFD will turn off. (If<br />

the ACK-key is not pressed, the flashing stays even if the alarm<br />

recovers, see also 5.3.7).<br />

Non-hold-mode: VFD will illuminate until the alarm recovers (pressing the<br />

ACK-key in this case will have no effect, see also 5.3.7).<br />

CHT: Illuminated when there are approx. 2cm left till chart end (option).<br />

BAT: Illuminated when the battery for setting data backup needs to be replaced.<br />

Flashes when the battery of the IC Memory Card needs to be replaced.<br />

4 - 4 IM 4H3B1-01E<br />

1<br />

1<br />

ALM<br />

CHT<br />

BAT<br />

ALM<br />

CHT<br />

BAT<br />

3<br />

3