-.<br />

UXO Safety Escort<br />

A UXO flashing checklist (Attachment B) will be used during flashing operations.<br />

Perform the flashing in a suitable container such as a 55-gallon drum or an empty<br />

dumpster.<br />

Always anticipate a high order detonation when performing a flashing and ensure that an<br />

appropriate exclusion area is established.<br />

Plan for the worst. Prepare the area to prevent brush fires by removing flammable<br />

vegetation from around the flashing site.<br />

Notifications of the local authorities will be made in accordance with the Site Work Plan.<br />

Have adequate fire fighting equipment in a stand-by status at the site to quickly extinguish<br />

any minor secondary fires before they can get out of hand.<br />

Use a fuel source other than wood and diesel or kerosene. These hydrocarbon fuels can<br />

create a secondary remediation problem if they are allowed to be absorbed into the ground<br />

around the flashing. Consider using some light wood dunnage ignited by a bed made of<br />

bags of Matchlite charcoal. The Matchlite ignites easily, burns very hot, and does not<br />

create any secondary contamination problems.<br />

Ignite all flashings remotely. A bag of black or smokeless powder ignited by an electric<br />

squib is the preferred method.<br />

The flashing must be observed for an additional 30 minutes after the flames and smoke<br />

die out.<br />

Thoroughly inspect the flashing no less than 12 hours after the flame and smoke have died<br />

out. Ensure that the material to be destroyed has been entirely consumed by the flashing<br />

and dispose of the residue.<br />

UXO safety escort services are petformed by IT UXO specialists for the purpose of ensuring the safety<br />

of non-UXO trained field personnel. Typically this service will be required when performing field<br />

inspection or sampling operations in areas suspected of being contaminated with UX.O.<br />

UXO safety escort is not considered to bean intrusive UXO operation and therefore can be petformed<br />

by a single UXO specialist. The two-man rule is not applicable to UXO safety escort operations. The<br />

purpose of providing a UXO safety escort is to ensure the avoidance of UXO and other hazards.<br />

Searching or excavating for UXO is not considered to be a part of the UXO safety escort function.<br />

=--The following procedures will be followed by IT UXO specialists when performing UXO safety escort<br />

Operations: