.<br />

1.3.2 Submit manufacturer’s data sheets, (HO).<br />

1.4 QUALITY ASSURANCE<br />

Perform work in accordance with Monterey County Department of Health regulations.<br />

Variances from the regulations will be negotiated in advance and documented in writing.<br />

PART 2 PRODUCTS<br />

2.1 <strong>LANDFILL</strong> GAS VENTS<br />

2,1 Pipes: HDPE, ASTM D2447, SDR 11.<br />

2.2 Screened section: HDPE, SDR 11 machine slotted, 0.02-inch slots.<br />

2.2 MONITORING PROBES<br />

2.1.1 Pipes: PVC to ASTM D3034, Schedule 40, flush threaded.<br />

2.1.2 Screened section: PVC, machine slotted, 0.02-inch slots.<br />

2.3 SEALING MATERIALS<br />

2.3.1<br />

2.3.2<br />

2.3.3<br />

2.3.4<br />

2.3.5<br />

Clean sand with the following gradations:<br />

Sieve Size Percent Passing<br />

# 3/8 100-1oo<br />

#3 87-99<br />

# 114 81-9S<br />

#4 18-62<br />

#6 o-5<br />

Bentonite: 3/8-inch pellets.<br />

Cement-Bentonite Grout: One sack of Type II Portland cement (94 pound<br />

sack) and 3 to 5 percent bentonite powder for each<br />

4-1/2 to 6-1/2 gallons of clean water.<br />

Pea Gravel: 1/4 - 3/8-inc~ washed.<br />

Bentonite Sluny<br />

SJ/5-14-96/SACTERC/lTORDCIUmn6W 02686-2 Landfill Gas Vents and<br />

Monitoring Probes