PLTEMP/ANL V3.6<br />

PLTEMP/ANL V3.6<br />

Hot Channel Factors included<br />

Hot Channel Factors Not Included<br />

Hot Channel Factors included<br />

Hot Channel Factors Not Included<br />

ONB=1.0 (Bergles&Rohsenow)<br />

ONB=1.0 (Forster&Greif)<br />

FI (Whittle&Forgan)<br />

ONB=1.0 (Bergles&Rohsenow)<br />

ONB=1.0 (Forster&Greif)<br />

FI (Whittle&Forgan)<br />

ONB=1.0 (Bergles&Rohsenow)<br />

ONB=1.0 (Forster&Greif)<br />

FI (Whittle&Forgan)<br />

ONB=1.0 (Bergles&Rohsenow)<br />

ONB=1.0 (Forster&Greif)<br />

FI (Whittle&Forgan)<br />

15<br />

Sieder-Tate<br />

15<br />

Dittus-Boelter<br />

1600<br />

1400<br />

Sieder-Tate<br />

Dittus-Boelter<br />

1600<br />

1400<br />

power [MW]<br />

10<br />

5<br />

nominal operation<br />

0<br />

0 2 4 6 8 10 12 14 16 18 20<br />

flow rate [m/s]<br />

power [MW]<br />

10<br />

5<br />

nominal operation<br />

0<br />

0 2 4 6 8 10 12 14 16 18 20<br />

flow rate [m/s]<br />

heat flux [W/cm 2 ]<br />

1200<br />

1000<br />

800<br />

600<br />

400<br />

400<br />

nominal operation<br />

nominal operation<br />

200<br />

200<br />

0<br />

0 2 4 6 8 10 12 14 16 18 20 0 2 4 6 8 10 12 14 16 18 20 0<br />

flow rate [m/s]<br />

flow rate [m/s]<br />

1200<br />

1000<br />

800<br />

600<br />

heat flux [W/cm 2 ]<br />

Fig. 5. Fig. 6.<br />

PLTEMP/ANL V3.6<br />

HEU<br />

ONB=1.0 (Bergles&Rohsenow)<br />

ONB=1.0 (Forster&Greif)<br />

FI (Whittle&Forgan)<br />

nominal operation<br />

UMo<br />

ONB=1.0 (Bergles&Rohsenow)<br />

ONB=1.0 (Forster&Greif)<br />

FI (Whittle&Forgan)<br />

nominal operation<br />

1600<br />

1400<br />

Sieder-Tate<br />

FABREGA (HEU)<br />

ONB=1.0 (Bergles&Rohsenow)<br />

ONB=1.0 (Forster&Greif)<br />

FI (Whittle&Forgan)<br />

Dittus-Boelter<br />

1600<br />

1400<br />

heat flux [W/cm 2 ]<br />

1200<br />

1000<br />

800<br />

600<br />

400<br />

200<br />

nominal operation<br />

nominal operation 200<br />

0<br />

0 2 4 6 8 10 12 14 16 18 200 2 4 6 8 10 12 14 16 18 20 0<br />

flow rate [m/s]<br />

flow rate [m/s]<br />

1200<br />

1000<br />

800<br />

600<br />

400<br />

heat flux [W/cm 2 ]<br />

Fig. 7.<br />

Figure 5. Power and flow limits in UMo – fuelled core, calculated by PLTEMP.<br />

Figure 6. Heat flux and flow limits in UMo – fuelled core, calculated by PLTEMP.<br />

Figure 7. Comparison of heat flux and flow limits for HEU and UMo – cores at forced flow<br />

operation conditions.<br />

6. Conclusions<br />

Detailed thermal-hydraulics analyses have been performed by PLTEMP/ANL V3.6 code for<br />

the BR2, HEU and LEU fuelled cores at steady-state operation under the conditions of forced<br />

flow cooling. The following results were obtained at nominal initial operation conditions, with<br />

included HCF and actual coolant flow of 10.4 m/s.<br />

For HEU core:<br />

- the maximum output power to ONB (Bergles & Rohsenow) is equal to 4.0 MW and to<br />

4.5 MW (Forster & Greif) for the single phase heat transfer correlation of Sieder-Tate<br />

and to 3.2 MW (B. & R.) and to 3.6 MW (F. & G.) for the single phase heat transfer<br />

201 of 455

Hooray! Your file is uploaded and ready to be published.

Saved successfully!