<strong>ABB</strong> i-bus ® <strong>EIB</strong>/<strong>KNX</strong><br />
<strong>ABB</strong> <strong>Powernet</strong> <strong>EIB</strong>/<strong>KNX</strong><br />
LEANtouch (monochrome),<br />
SMARTtouch (monochrome, colour)<br />
Type: 6x36/30M…, 6x36/100x…, 6x36/100CB…<br />
Parameters: Room thermostat<br />
The default setting for the values<br />
is printed in bold type.<br />
Setpoints heating:<br />
– Base setpoint in °C (16…31) 21<br />
Comfort temperature heating<br />
– Lowering standby operation heating 2<br />
in K (1…15)<br />
– Lowering night operation heating 4<br />
in K (1…15)<br />
– Setpoint frost protection 7<br />
in °C (4…10)<br />
– Level distance from the base level 1…3…5<br />
to the additional level in K<br />
Controlling/Control value heating:<br />
– Output of control value continuously<br />
switched<br />
– Control type Two-position controller<br />
PI controller<br />
Only for two-position controller:<br />
– Hysteresis 0.3K / 0.5K / 0.7K / 1K / 1.5K / 2K<br />
– Lowering of hysteresis Inactive<br />
0.2 K/min<br />
0.1 K/min<br />
0.06 K/min<br />
0.04 K/min<br />
0.03 K/min<br />
0.02 K/min<br />
– Cycle time of the control value in mm:ss 14:50<br />
(03:00…60:00)<br />
Only for continuous controller:<br />
– Change for automatic sending of Inactive / 2% / 5% / 10%<br />
control value<br />
Only for PI controller:<br />
– Control parameters via installation type<br />
free setting of parameters<br />
Only for installation type:<br />
– Type of heating system Warm water heating (1.5K/100min)<br />
Electric heating (1.5K/50min)<br />
Floor heating (4K/200min)<br />
Only for free parameterisation:<br />
– Proportional area 1.0K / 1.5K / 2.0K / 2.5K / 3K / 4K /<br />
6K / 8K / 10K<br />
– Reset time in min. I part inactive / 10 min / 20 min /<br />
30 min / … / 100 min / … / 240 min<br />
Only for switched controller:<br />
– PWM cycle 3min / 5min / 10min / 15min / 20min /<br />
30min / 40min / 50min / 60min<br />
– PWM cycle is 0% up to control value 0% / 10% / 20% / 30%<br />
– PWM cycle is 100% up to control value 70% / 80% / 90% / 100%<br />
– Effective mode Normal<br />
Inverted<br />
Only for additional heating:<br />
– Hysteresis (one-sided) 0.3K / 0.5K / 0.7K / 1.0K / 1.5K / 2.0K<br />
– Cycle time for automatic sending of the 14:50<br />
control value e in mm:ss (03:00…60:00)<br />
– Control value type switched<br />
quasi contin. (1 Byte: 0% or 100%)<br />
– Effective mode Normal<br />
Inverted<br />