6.6.3 Wastewater<br />

No wastewater other than sanitary (discussed in Section 6.2) is produced at the <strong>site</strong>.<br />

6.6.4 Stormwater<br />

V3’s <strong>site</strong> visit indicates stormwater runoff from the property flows into stormwater manholes<br />

located throughout the parking lot <strong>and</strong> pavement south of the building. No environmental<br />

concerns were identified.<br />

6.6.5 Drains <strong>and</strong> Sumps<br />

The following drains <strong>and</strong> sumps were observed at the <strong>site</strong>:<br />

Location Type Water observed?<br />

Building<br />

Parking<br />

lots <strong>and</strong><br />

pavement<br />

south of<br />

building<br />

South of<br />

China<br />

King<br />

Buffet<br />

Floor drains<br />

throughout<br />

building<br />

(including<br />

bathrooms)<br />

Storm sewer<br />

manholes<br />

Sheens, odors or<br />

other evidence of<br />

concern?<br />

Discharge<br />

Point<br />

No No Sanitary sewer No<br />

Yes<br />

Grease trap No No<br />

No; observations limited<br />

Municipal<br />

storm sewer<br />

Connected to<br />

municipal<br />

sanitary sewer<br />

REC – Yes/No<br />

No<br />

No – grease<br />

trap cleaned<br />

out on a<br />

regular basis<br />

6.7 Underground (USTs) <strong>and</strong> Above-Ground (ASTs) Storage Tanks<br />

No indication of USTs was noted by V3 during the <strong>site</strong> visit.<br />

According to Mr. Phil Prassas, Jr., no historical ASTs or USTs were located on the <strong>site</strong>. Based<br />

on the records review presented in Section 5.0, no records of a UST were found for the <strong>site</strong><br />

address.<br />

The following AST was observed at the <strong>site</strong>:<br />

Location<br />

South of<br />

ACE<br />

Hardware<br />

Capacity<br />

(gallons)<br />

Contents Status Secondary<br />

Containment<br />

1,000 Liquid In use Over concrete<br />

Propane<br />

pavement<br />

Staining – if yes REC or de minimis<br />

No<br />

6.8 Indications of Polychlorinated Biphenyls (PCBs)<br />

The following equipment that potentially contains PCBs was observed during V3’s <strong>site</strong> visit.<br />

Location Equipment PCB labeling Conditions Staining? If yes, REC<br />

Phase I Environmental Site Assessment V3 Companies of Illinois • 19<br />

Spartans’ Square Shopping Center February 2008<br />

Romeoville, Illinois 07292