15.06.2014 Views

comprehensive site investigation and remediation objectives report

comprehensive site investigation and remediation objectives report

comprehensive site investigation and remediation objectives report

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Illinois Environmental Protection Agency Laboratory<br />

825 N. Rutledge Springfield, Illinois 62702 217.782.9780<br />

LABORATORY RESULTS<br />

Name:<br />

SPARTAN SQ SHOPPING CENTER<br />

Project/Facility Number: 1970905180<br />

Date Received : 11/20/08<br />

Funding Code:<br />

Trip ID:<br />

PR50<br />

Visit Number:<br />

Temperature C: 6.00<br />

Notes <strong>and</strong> Definitions<br />

L<br />

J5<br />

J3<br />

J2<br />

ND<br />

NR<br />

Actual value not known, but known to be greater than value shown. To be used when the concentration of the analyte is above the<br />

acceptable level for quantitation. Value shown is the highest acceptable level for quantitation.<br />

Blank spike failed high, result was non-detect - impact on data may be minimal.<br />

The <strong>report</strong>ed value failed to meet the established quality control criteria for either precision or accuracy possibly due to matrix<br />

effects.<br />

Internal St<strong>and</strong>ard criteria was not met.<br />

Analyte NOT DETECTED at or above the <strong>report</strong>ing limit<br />

Not Reported<br />

* Non-NELAP accredited<br />

S817728-03, -04: Insufficent sample volume received to perform a matrix spike <strong>and</strong> matrix spike duplicate for Methods 8081 <strong>and</strong> 8082.<br />

Therefore, NELAC <strong>and</strong> method requirements were not met.<br />

S817728-02: Hydrocarbon Identification by FID- No significant hydrocarbon pattern detected.<br />

S817728-06 Hydrocarbon Identification by FID- No significant hydrocarbon pattern detected.<br />

Unable to perform pH analysis on samples: S817728-03, S817728-04 <strong>and</strong> S817728-09 due to entire sample volume consumed for<br />

pesticide <strong>and</strong> semi-volatile analysis.<br />

Method 8270 samples S817728-08 <strong>and</strong> -09: Tentatively Identified Compounds (TICs) were detected in the semivolatile analysis. Please<br />

contact the laboratory if additional information about the TICs is needed.<br />

Method 8260 samples S817728-08, <strong>and</strong> S817728-11: Tentatively Identified Compounds (TICs) were detected in the volatile analysis.<br />

Please contact the laboratory if additional information about the TICs is needed.<br />

Method 8260 samples S817728-12, -13, -14, <strong>and</strong> -15 : No matrix spike/matrix spike duplicate was performed for the analysis of these<br />

methanol extracts. NELAC <strong>and</strong> method requirements were not met.<br />

Report Authorized by:<br />

The results in this <strong>report</strong> apply to the samples analyzed in accordance with the chain of<br />

custody document. This analytical <strong>report</strong> must be reproduced in its entirety. Test results<br />

meet all requirements of NELAC (accredited by Florida DOH #E37645).<br />

Reported:<br />

12/22/08 13:04<br />

Page 52 of 52

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!