Illinois Environmental Protection Agency Laboratory<br />

825 N. Rutledge Springfield, Illinois 62702 217.782.9780<br />

LABORATORY RESULTS<br />

Name:<br />

SPARTAN SQ SHOPPING CENTER<br />

Project/Facility Number: 1970905180<br />

Date Received : 11/19/08<br />

Funding Code:<br />

Trip ID:<br />

PR50<br />

Visit Number:<br />

Temperature C: 6.00<br />

Notes <strong>and</strong> Definitions<br />

V<br />

L<br />

J5<br />

J3<br />

J2<br />

ND<br />

NR<br />

Indicates the analyte was detected in both the sample <strong>and</strong> the associated method blank <strong>and</strong> was outside method blank acceptance<br />

criteria.<br />

Actual value not known, but known to be greater than value shown. To be used when the concentration of the analyte is above the<br />

acceptable level for quantitation. Value shown is the highest acceptable level for quantitation.<br />

Blank spike failed high, result was non-detect - impact on data may be minimal.<br />

The <strong>report</strong>ed value failed to meet the established quality control criteria for either precision or accuracy possibly due to matrix<br />

effects.<br />

Internal St<strong>and</strong>ard criteria was not met.<br />

Analyte NOT DETECTED at or above the <strong>report</strong>ing limit<br />

Not Reported<br />

* Non-NELAP accredited<br />

Method 8260 samples S817633-01, -02, -03, -04, -05,-06, -07, -08, -09, -11, -12, -13, -14, -15: Blank Spike was not run due to a<br />

laboratory error therefore the method <strong>and</strong> NELAC requirements were not met. The <strong>report</strong>ed values are not affected by this omission.<br />

Method 8270 samples S817633-03, -04, -05, -11, -12, -16, <strong>and</strong> -19: Tentatively Identified Compounds (TICs) were detected in the<br />

semivolatile analysis. Please contact the laboratory if additional information about the TICs is needed.<br />

Method 8260 sample S817633-13: Tentatively Identified Compounds (TICs) were detected in the volatile analysis. Please contact the<br />

laboratory if additional information about the TICs is needed.<br />

Report Authorized by:<br />

The results in this <strong>report</strong> apply to the samples analyzed in accordance with the chain of<br />

custody document. This analytical <strong>report</strong> must be reproduced in its entirety. Test results<br />

meet all requirements of NELAC (accredited by Florida DOH #E37645).<br />

Reported:<br />

12/22/08 12:53<br />

Page 82 of 82