Ms. Dawn Caldwell<br />

Village of Romeoville<br />

February 6, 2008<br />

Page 4<br />

<strong>and</strong> groundwater analytical results. Laboratory <strong>report</strong>s <strong>and</strong> chains of custody documents are<br />

provided in Attachment C.<br />

Soil Analytical Results<br />

The dry cleaning solvent tetrachloroethene (PCE) was detected in nine of the ten soil<br />

samples submitted to laboratory for chemical analysis (Table 1). However, only two soil<br />

samples [SM-GP-07(10-12) or SM-GP-08 (8-10)] exceeded residential or<br />

industrial/commercial ROs (Table 1).<br />

Trichloroethene (TCE) was detected in one of the soil samples but below the RO. No other<br />

VOC constituents were detected above laboratory detection limits in any of the soil samples<br />

analyzed.<br />

Groundwater Analytical Results<br />

PCE was detected in the groundwater samples collected from temporary monitoring wells<br />

SM-GP-07 <strong>and</strong> SM-GP-08 at concentrations exceeding the Class I <strong>and</strong> Class II groundwater<br />

ROs (Table 2).<br />

No other VOC constituents were detected above laboratory detection limits in groundwater<br />

samples collected from the temporary monitoring wells.<br />

FINDINGS AND CONCLUSIONS<br />

Based on information obtained during the Phase II ESA, V3 presents the following findings<br />

<strong>and</strong> conclusions:<br />

• PCE was detected in several soil <strong>and</strong> groundwater samples. The presence of PCE in<br />

the subsurface indicates that dry cleaning operations were historically performed in<br />

what is now the Mrs. Clean Laundromat tenant space.<br />

• Additional <strong>investigation</strong> is needed to determine specific contaminant source areas <strong>and</strong><br />

to delineate the vertical <strong>and</strong> horizontal extents of the PCE impacts. These data will be<br />

useful in evaluating remedial alternatives <strong>and</strong> costs.<br />

• Additional <strong>investigation</strong> will be required to determine whether the adjacent LUST<br />

incidents <strong>and</strong> on-<strong>site</strong> hydraulic lifts have impacted the Site.<br />

E:\2007\07292\Reports\Natural Resources\Environ\Phase II ESA\Phase II Report\07292 Phase II FINAL 021808.doc