Soil samples were analyzed for one or more of the following: VOCs, SVOCs, PNAs <strong>and</strong> TAL<br />

metals constituents. Based on the nature of the constituents associated with hydraulic lifts <strong>and</strong><br />

the lack of field indications of contamination, no groundwater samples were collected.<br />

The sampling locations for this REC are provided in Figure 3.2.<br />

4.5 REC 3 – EAST ADJACENT GAS STATION<br />

The following sampling program was performed to characterize REC 3:<br />

Soil boring (SM-GP-16 <strong>and</strong> SM-GP-18) were advanced by V3 to characterize potential<br />

subsurface impacts (Figure 3.2) associated with the east adjacent gas station. Refusal was<br />

encountered at 14 <strong>and</strong> 17 feet bgs, respectively. The boring was advanced on the northeast<br />

side of the Site, west of well MW-10 advanced by ERS as part of the Site <strong>investigation</strong> for the<br />

east adjacent gas station (former Clark Station). No field indications of contamination were<br />

observed in boring SM-GP-16. Soil samples were not collected from the boring.<br />

Groundwater samples were collected from temporary monitoring wells (SM-GP-16 <strong>and</strong> SM-GP-<br />

18) to characterize groundwater conditions. In addition, groundwater from a permanent<br />

monitoring well, MW-10, installed by ERS, was also sampled. Prior to groundwater sampling,<br />

one round of static water level measurements was taken from the monitoring wells prior to<br />

commencing any purging <strong>and</strong> sampling activities. The wells were purged <strong>and</strong> sampled using<br />

the micro-purge low-flow method. Upon stabilization of field parameters, the samples were<br />

collected for VOCs. PNAs were also sampled at MW-10 to update the historical sample. No<br />

evidence of odors or sheen was noted in the groundwater samples.<br />

The sampling locations for this REC are provided in Figure 3.2.<br />

Comprehensive Site Investigation Report V3 Companies, 21<br />

Spartans’ Square Shopping Center May 2010