You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
ENGINEERING<br />
A<br />
TOLERANCES – continued<br />
INCH SYSTEM BEARINGS - continued<br />
Bearing<br />
types (1)<br />
TS<br />
TSF<br />
TSL<br />
TDI<br />
TDIT<br />
TDO<br />
Cone stand<br />
Bore<br />
Over Incl.<br />
mm<br />
in.<br />
mm<br />
in.<br />
Inch bearing tolerances<br />
<strong>Precision</strong> bearing class<br />
3 0 00 000<br />
Max. Min. Max. Min. Max. Min. Max. Min.<br />
mm<br />
in.<br />
mm<br />
in.<br />
0.000 101.600 +0.102 -0.102<br />
mm<br />
in.<br />
0.0000 4.0000 +0.0040 -0.0040<br />
101.600 266.700 +0.102 -0.102<br />
(2) (2) (2) (2) (2) (2)<br />
4.0000 10.5000 +0.0040 -0.0040<br />
266.700 304.800 +0.102 -0.102 – – – –<br />
10.5000 12.0000 +0.0040 -0.0040 – – – –<br />
304.800 406.400 +0.102 -0.102 – – – – – –<br />
12.0000 16.0000 +0.0040 -0.0040 – – – – – –<br />
406.400<br />
– – – – – –<br />
(2) (2)<br />
16.0000 – – – – – –<br />
mm<br />
in.<br />
mm<br />
in.<br />
mm<br />
in.<br />
mm<br />
in.<br />
mm<br />
in.<br />
Cone Stand. Cone stand<br />
is a measure of the<br />
variation in cone raceway<br />
size, taper and roller<br />
diameter. This is checked<br />
by measuring the axial<br />
location of the reference<br />
surface of a master cup<br />
or other type gage with<br />
respect to the reference<br />
cone face.<br />
Bearing<br />
types (1)<br />
TS<br />
TSF (3)<br />
TSL<br />
TDI<br />
TDIT<br />
Cup stand<br />
Bore<br />
Over Incl.<br />
mm<br />
in.<br />
mm<br />
in.<br />
Inch bearing tolerances<br />
<strong>Precision</strong> bearing class<br />
3 0 00 000<br />
Max. Min. Max. Min. Max. Min. Max. Min.<br />
mm<br />
in.<br />
mm<br />
in.<br />
0.000 101.600 +0.102 -0.102<br />
mm<br />
in.<br />
0.0000 4.0000 +0.0040 -0.0040<br />
101.600 266.700 +0.102 -0.102<br />
(2) (2) (2) (2) (2) (2)<br />
4.0000 10.5000 +0.0040 -0.0040<br />
266.700 304.800 +0.102 -0.102 – – – –<br />
10.5000 12.0000 +0.0040 -0.0040 – – – –<br />
304.800 406.400 +0.102 -0.102 – – – – – –<br />
12.0000 16.0000 +0.0040 -0.0040 – – – – – –<br />
406.400<br />
– – – – – –<br />
(2) (2)<br />
16.0000 – – – – – –<br />
mm<br />
in.<br />
mm<br />
in.<br />
mm<br />
in.<br />
mm<br />
in.<br />
mm<br />
in.<br />
Cup Stand. Cup stand is a<br />
measure of the variation<br />
in cup I.D. size and<br />
taper. This is checked<br />
by measuring the axial<br />
location of the reference<br />
surface of a master plug<br />
or other type gage with<br />
respect to the reference<br />
face of the cup.<br />
(1) Not all types and sizes are listed in this catalog. Please contact your <strong>Timken</strong> representative <strong>for</strong> further in<strong>for</strong>mation.<br />
(2) These sizes manufactured as matched assemblies only.<br />
(3) Stand <strong>for</strong> flanged cup is measured from flange backface (seating face).<br />
74 TIMKEN MACHINE TOOL CATALOG