O<br />

C<br />

w<br />

Report of Committee on Ordinances<br />

65 09<br />

21<br />

b<br />

It shall be placed on a permanent foundation which itself is<br />

securely anchored and to which the structune is securely anchored<br />

so that it will resist flotation lateral movement and hydrostatic and<br />

hydrodynamic pressures Anchoring may include but not be<br />

limited to the use of over the top or frame tiles to ground anchors<br />

c<br />

d<br />

It shall be installed using methods and practices<br />

flood damage<br />

Adequate access and drainage should be provided<br />

which minimize<br />

e Recreational vehicles shall either be 0111 site for fewer than<br />

180 consecutive days and be fully IicElnsed and ready for<br />

hiahway use or meet all the aeneral s tandards of section<br />

15 44 150 A and the elevation and anchorina reauirement of<br />

section 15 44 150 A 5 a and b and 15 44 150 b 2 a b c<br />

and d for a manufactured home A recreational vehicle is<br />

ready for hiahway use if it is on its wheelis or iackina system<br />

is attached to the site only by Quick dis onnect type utilities<br />

and security devices and has no PElrmanently attached<br />

additions<br />

3 Nonresidential Construction New construction and substantial<br />

improvement of any commercial industrial or other nonresidential<br />

structure shall either have the lowest floor including basement elevated<br />

to the level of the base flood elevation or<br />

together with attendant utility<br />

and sanitary facilities shall<br />

a<br />

b<br />

c<br />

Be flood proofed so that below an elevation of one foot above the<br />

base flood level the structure is watertight with walls substantially<br />

impermeable to the passage of water<br />

Have structural components capable of resisting hydrostatic and<br />

hydronamic loads and effects of buoyancy and<br />

Be certified by a registered professional<br />

en lineer or architect that<br />

the design and methods of construction are in accordance with<br />

acceptable standards of practice for meetin l the provisions of this<br />

subsection Such certifications shall be provided to the official as<br />

setforth in Section 15 44 130 c 2