Report of Committee on Ordinances<br />

65 09<br />

23<br />

2 Construction Methods<br />

a Elevation All new buildings structures or substantial<br />

improvements shall be elevated so that the lowest supporting<br />

member excluding pilings or columns is located no lower than<br />

the base flood elevation level with all space below the lowest<br />

supporting member open so as not to impede the flow of water<br />

except for breakaway walls as provided<br />

for in subsection<br />

15 44 150 C 2 d of this section<br />

b<br />

Structural Support<br />

i All new buildings structures or substantial improvements<br />

shall be securely anchored on pilingls<br />

or columns<br />

ii<br />

Hi<br />

All pilings and columns and the attached structures shall<br />

be anchored to resist flotation collapse and lateral<br />

movement due to the effect of wind and water loads acting<br />

simultaneously on all building components The anchoring<br />

and support system shall be designed with wind and water<br />

loading values which equal or exceed the one hundred<br />

year mean recurrence interval one percent annual chance<br />

floods and winds<br />

There shall be no fill used for structural support<br />

c Certification Compliance with the provIsions<br />

of<br />

subsection C 2 a and b of this section shall be certified by a<br />

registered professional engineer<br />

or architect including design<br />

specifications and plans for construction<br />

d<br />

Space Below the Lowest Floor<br />

i Any alteration repair reconstructi on or improvement to a<br />

structure started after the enac1tment<br />

of the ordinance<br />

codified in this chapter shall not Emclose the space below<br />

the lowest floor unless breakaway walls are used as<br />

provided for in this section<br />

Ii Nonsupporting breakaway wall lattice work or mesh<br />

screening shall be allowed below the base flood elevation