Alternative Reader Wiring Guide - Best Access Systems
Alternative Reader Wiring Guide - Best Access Systems
Alternative Reader Wiring Guide - Best Access Systems
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Alternative</strong> <strong>Reader</strong> <strong>Wiring</strong> <strong>Guide</strong><br />
20.4. Indala <strong>Reader</strong> ARK-501<br />
(Not evaluated by UL)<br />
20.4.1 <strong>Wiring</strong> the BAS-1300<br />
Single <strong>Reader</strong> Interface Module<br />
GND<br />
BZR<br />
LED<br />
CLK/D1<br />
TYPICAL SOFTWARE SETTINGS<br />
1. <strong>Reader</strong> Type = Wiegand/Prox<br />
2. Keypad Type = eight bit output<br />
DAT/D0<br />
+12V<br />
TR+<br />
TR-<br />
SG<br />
Suggested<br />
Color Code<br />
(White)<br />
Splice Here<br />
Color<br />
Code<br />
White<br />
<strong>Reader</strong> Cable<br />
(Green)<br />
Green<br />
Do not<br />
connect<br />
(Blue)<br />
(Orange)<br />
Blue<br />
Orange<br />
1 2 3<br />
4 5 6<br />
7 8 9<br />
* 0 #<br />
(Brown)<br />
Brown<br />
ARK-501 Prox<br />
<strong>Reader</strong>/Keypad<br />
Linear Power<br />
Supply<br />
-<br />
+<br />
(Black)<br />
(Red)<br />
Black<br />
(Red)<br />
Shield<br />
(Screen)<br />
Do not connect<br />
EARTH GROUND<br />
revision 7 — 101