Motorola Indala <strong>Reader</strong>s<br />
20.4.2 <strong>Wiring</strong> the BAS-1320<br />
Dual <strong>Reader</strong><br />
Interface Module<br />
READER 1<br />
VO<br />
LED<br />
BZR<br />
TYPICAL SOFTWARE SETTINGS<br />
1. <strong>Reader</strong> Type = Wiegand/Prox<br />
2. Keypad Type = eight bit output<br />
* Use the 1320 in Unregulated Mode (jumper J2)<br />
D1/CLK<br />
D0/DATA<br />
GND<br />
Splice Here<br />
<strong>Reader</strong> Cable<br />
VO<br />
LED<br />
Suggested<br />
Color Code<br />
(White)<br />
Color<br />
Code<br />
White<br />
READER 2<br />
BZR<br />
D1/CLK<br />
D0/DATA<br />
Do not<br />
connect<br />
(Green)<br />
(Blue)<br />
(Orange)<br />
Green<br />
Blue<br />
Orange<br />
1 2 3<br />
4 5 6<br />
7 8 9<br />
* 0 #<br />
GND<br />
(Brown)<br />
Brown<br />
ARK-501 Prox<br />
<strong>Reader</strong>/Keypad<br />
12 VDC<br />
Linear<br />
Power Supply<br />
-<br />
+<br />
(Black)<br />
(Red)<br />
Black<br />
(Red)<br />
EARTH GROUND<br />
Shield<br />
(Screen)<br />
Do not connect<br />
102 — revision 7