Alternative Reader Wiring Guide - Best Access Systems
Alternative Reader Wiring Guide - Best Access Systems
Alternative Reader Wiring Guide - Best Access Systems
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Alternative</strong> <strong>Reader</strong> <strong>Wiring</strong> <strong>Guide</strong><br />
17. Keri <strong>Systems</strong> <strong>Reader</strong>s<br />
Use the following diagrams to wire (single wire LED control) Single/Dual <strong>Reader</strong> Interface Modules and<br />
Keri <strong>Systems</strong> readers.<br />
17.1. Cascade and Sierra <strong>Reader</strong>s (P-300, P-400, P-500, P-600 with<br />
Keypad, P-700)<br />
(Not evaluated by UL)<br />
The Keri <strong>Systems</strong> <strong>Reader</strong>s operate at 12 VDC. All the reader models require an alternate 12 VDC power<br />
source when being connected to the Single <strong>Reader</strong> Interface. They cannot be powered from the reader<br />
interface module. The readers also feature Prox by HID Technology (optional) which allows them to be<br />
compatible with ProxCard II, ISO Prox II, ProxKey II in 26-bit and other customer HID card format.<br />
Note:<br />
The keypad for the P-600 is 8-bit output.<br />
17.1.1 <strong>Wiring</strong> the BAS-1300<br />
TYPICAL SOFTWARE SETTINGS<br />
1. <strong>Reader</strong> Type = Wiegand/Prox<br />
2. Jumper J4 must be set to 12 VDC<br />
3. LED Mode = Single Wire LED Control<br />
Cascade <strong>Reader</strong> /<br />
Sierra <strong>Reader</strong><br />
Silver - Shield<br />
Black - Ground<br />
Blue - Beeper<br />
Brown - Single LED<br />
White - Data 1<br />
Orange - not used<br />
Green - Data 0<br />
Red - Power<br />
Single <strong>Reader</strong> Interface Module<br />
GND<br />
BZR<br />
LED<br />
CLK/D1<br />
DAT/D0<br />
+12V<br />
TR+<br />
TR-<br />
SG<br />
GND<br />
12 V Power Supply<br />
revision 7 — 81