<strong>Alternative</strong> <strong>Reader</strong> <strong>Wiring</strong> <strong>Guide</strong><br />
11.3. Dorado <strong>Reader</strong> Model 611<br />
(Not evaluated by UL)<br />
The Dual <strong>Reader</strong> Interface must have Jumper J4 ON for 5 VDC Operation or<br />
External Power supply must be used as shown below<br />
Dual <strong>Reader</strong> Interface Module<br />
VO<br />
LED<br />
See manual for voltage and<br />
current recommendations.<br />
Software Settings:<br />
• <strong>Reader</strong> interface All other<br />
readers<br />
• One Wire LED Control<br />
READER 1<br />
BZR<br />
D1/CLK<br />
D0/DATA<br />
GND<br />
VO<br />
Brown wire<br />
LED<br />
White wire<br />
OFF<br />
READER 2<br />
BZR<br />
D1/CLK<br />
Green wire<br />
Yellow wire<br />
A<br />
B<br />
C<br />
D0/DATA<br />
D<br />
GND<br />
Red wire<br />
ON<br />
Black wire<br />
GND<br />
VDC 5 VDC<br />
Power Supply (35 mA)<br />
Dorado<br />
<strong>Reader</strong><br />
Model 611<br />
11.4. Dorado Elevator <strong>Reader</strong> 570<br />
This reader operates at 35 mA at +5.5 volts (regulated 4.75 to 5.75).<br />
If you are going to power the reader from the BAS-1320, set jumper 4 to the ON position for 5 volts and<br />
jumper 2 for regulated mode.<br />
A four-position DIP switch is located on the reader circuit board to control the reader options. The reader<br />
should be set to Mode 6. Note that the fourth switch is not used and should be set to the OFF position.<br />
Mode A B C D Function<br />
6 ON off ON off ABA card, all bits Wiegand<br />