Motorola Indala <strong>Reader</strong>s<br />
20.7. Indala EM4525F <strong>Reader</strong><br />
This reader operates at 10 - 14 VDC. The average current draw is 75 mA.<br />
20.7.1 <strong>Wiring</strong> the BAS-1300<br />
TYPICAL SOFTWARE SETTINGS<br />
1. <strong>Reader</strong> Type = WIEGAND/PROX<br />
2. Keypad = NO KEYPAD<br />
3. LED Mode = 2-WIRE LED CONTROL<br />
Single <strong>Reader</strong><br />
Interface Module<br />
Black<br />
Blue<br />
Brown<br />
White<br />
Green<br />
Red<br />
GND<br />
BZR<br />
LED<br />
CLK/D1<br />
DATA/D0<br />
VO<br />
20.7.2 <strong>Wiring</strong> the BAS-1320<br />
TYPICAL SOFTWARE SETTINGS<br />
1. <strong>Reader</strong> Type = WIEGAND/PROX<br />
2. Keypad = NO KEYPAD<br />
3. LED Mode = 2-WIRE LED CONTROL<br />
Red<br />
Brown<br />
Blue<br />
White<br />
Green<br />
Black<br />
Dual <strong>Reader</strong><br />
Interface Module<br />
VO<br />
LED<br />
BZR<br />
CLK/D1<br />
DATA/D0<br />
GND<br />
<strong>Reader</strong> 1<br />