Alternative Reader Wiring Guide - Best Access Systems
Alternative Reader Wiring Guide - Best Access Systems
Alternative Reader Wiring Guide - Best Access Systems
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Alternative</strong> <strong>Reader</strong> <strong>Wiring</strong> <strong>Guide</strong><br />
22.2. Touch Card <strong>Reader</strong> (TC-100)<br />
This reader operates between 9 and 24 VDC. The reader has a current draw of 125 mA to 135 mA, therefore<br />
it must be connected to an alternate power supply. The reader outputs a standard Wiegand format and uses<br />
the standard single wire LED control. Follow the diagram below for the correct wiring procedure.<br />
22.2.1 <strong>Wiring</strong> the BAS-1300<br />
TYPICAL SOFTWARE SETTINGS<br />
1. <strong>Reader</strong> Type = WIEGAND/PROX<br />
2. Keypad = NO KEYPAD<br />
3. LED Mode = 1-WIRE LED CONTROL<br />
ACCESS<br />
SPECIALTIES<br />
TC-100<br />
(Not Used)<br />
Single <strong>Reader</strong><br />
Interface Module<br />
GND<br />
BZR<br />
LED<br />
CLK/D1<br />
DATA/D0<br />
Brown<br />
White<br />
Green<br />
VO<br />
Red<br />
Black<br />
Alternate Power Supply<br />
+<br />
_<br />
12 VDC<br />
revision 7 — 115