<strong>Alternative</strong> <strong>Reader</strong> <strong>Wiring</strong> <strong>Guide</strong><br />

6. Bewator <strong>Reader</strong>s<br />

6.1. Remote Card <strong>Reader</strong> Model BC18<br />

The reader does not require a separate power supply when being connected to the Dual <strong>Reader</strong> Interface<br />

Module. However, the reader will need an alternate 5 VDC power connection if it is connected to a Single<br />

<strong>Reader</strong> Interface Module. The recommended draw is 40 mA and the reader needs to be connected to 5 VDC.<br />

Also, be sure to set up Jumper J2 for REGULATED power mode. J4 should be configured for 5 VDC.<br />

Recommended operating temperature: -10° to 55° C<br />

6.1.1 <strong>Wiring</strong> the BAS-1300<br />

TYPICAL SOFTWARE SETTINGS<br />

1. <strong>Reader</strong> Type = ALL OTHER READERS<br />

2. Keypad = NO KEYPAD<br />

3. LED Mode = 1-WIRE LED CONTROL<br />

BEWATOR<br />

Single <strong>Reader</strong> Interface Module<br />

GND<br />

BZR<br />

LED<br />

CLK/D1<br />

DATA/D0<br />

VO<br />

Green<br />

Yellow<br />

Grey<br />

BC<br />

18<br />

5 VDC -<br />

Powersupply +<br />

Blue<br />

White<br />

revision 7 — 29