19.2. Integrated Engineering PX007 Mifare <strong>Reader</strong><br />
The following information applies for these Integrated Engineering reader models: PX007Z/MFSNR,<br />
PX007MF/Read Only, and PX007MF/RS232(B).<br />
The reader operates between 4.75 and 12.25 VDC and has an average draw of 50 mA. Therefore, the reader<br />
can be directly powered from the reader interface modules. The reader can output both standard Clock and<br />
Data or standard Wiegand data. To get proper LED functionality, the reader must be set up for 2-wire LED<br />
mode. Please follow the diagrams for proper wiring of the reader.<br />
19.2.1 <strong>Wiring</strong> the BAS-1300<br />
TYPICAL SOFTWARE SETTINGS<br />
1. <strong>Reader</strong> Type = WIEGAND/PROX<br />
2. Keypad = NO KEYPAD<br />
3. LED Mode = 2-WIRE LED CONTROL<br />
Terminal on Back<br />
of <strong>Reader</strong><br />
Single <strong>Reader</strong><br />
Interface Module<br />
GND<br />
5-12 VDC<br />
Ground<br />
Clock / D0<br />
Data / D1<br />
Green LED<br />
Red LED<br />
(8)<br />
(7)<br />
(6)<br />
(5)<br />
(4)<br />
(3)<br />
(2)<br />
(1)<br />
INTEGRATED<br />
ENGINEERING<br />
BZR<br />
LED<br />
CLK/D1<br />
DATA/D0<br />
VO<br />