11. Dorado <strong>Reader</strong>s<br />

Use the following diagrams to wire Single/Dual <strong>Reader</strong> Interface Modules and Dorado readers.<br />

11.1. Dorado <strong>Reader</strong> Model 644<br />

For the Dorado <strong>Reader</strong> 644, a 16-position rotary switch (Trim POT) is now used for reader configuration. It<br />

is located inside the housing on the circuit board. The LED control is standard single wire. The reader should<br />

be configured to setting 5 (ABA cards, all bits, Wiegand).<br />

For Radionics hardware and cards, the reader mode is Mag with Wiegand output.<br />

(Not evaluated by UL)<br />

11.1.1 <strong>Wiring</strong> the BAS-1300<br />

TYPICAL SOFTWARE SETTINGS<br />

1. <strong>Reader</strong> Type = All other readers<br />

Black<br />

Brown<br />

Yellow<br />

White<br />

Green<br />

Red<br />

GND<br />

BZR<br />

LED<br />

CLK/D1<br />

DAT/D0<br />

+12V<br />

TR+<br />

Dorado <strong>Reader</strong><br />

Model 644<br />

TR-<br />

SG<br />

Single <strong>Reader</strong> Interface Module<br />

GND<br />

VDC 5 VDC<br />

Power Supply<br />

revision 7 — 45