20.2. Indala <strong>Reader</strong>s ASR-503, ASR-505, ASR-110, ASR-112<br />

(Not evaluated by UL)<br />

20.2.1 <strong>Wiring</strong> the BAS-1300<br />

TYPICAL SOFTWARE SETTINGS<br />

1. <strong>Reader</strong> Type = Wiegand/Prox<br />

2. No keypad<br />

Power Supply<br />

GND<br />

12 VDC<br />

<strong>Reader</strong> Current<br />

Requirements:<br />

ASR-503, 505: 45 mA<br />

ASR-110, 112: 180 mA<br />

DC+<br />

GND - DATA RTN<br />

Red<br />

Black<br />

Single <strong>Reader</strong><br />

Interface Module<br />

GND<br />

Red LED<br />

Brown<br />

BZR<br />

Green LED<br />

Data "1"<br />

Orange<br />

White<br />

LED<br />

CLK/D1<br />

Data "0"<br />

Green<br />

DAT/D0<br />

INDALA READERS<br />

ASR-503<br />

ASR-505<br />

ASR-110, ASR-112<br />

+12V<br />

TR+<br />

TR-<br />

SG<br />