Alternative Reader Wiring Guide - Best Access Systems
Alternative Reader Wiring Guide - Best Access Systems
Alternative Reader Wiring Guide - Best Access Systems
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Alternative</strong> <strong>Reader</strong> <strong>Wiring</strong> <strong>Guide</strong><br />
11.2. Dorado <strong>Reader</strong> Model 780<br />
(Not evaluated by UL)<br />
11.2.1 <strong>Wiring</strong> the BAS-1300<br />
Software Settings:<br />
• <strong>Reader</strong> interface All other readers<br />
• Dorado LED control<br />
• 8 Bit Pin numbers<br />
• Requires Firmware Revision<br />
for the Dual <strong>Reader</strong> Interface<br />
10278 0 MR-52<br />
R1.04a<br />
MSC-C97-8 STO<br />
or for Single <strong>Reader</strong> Interface<br />
10241 2 MR-50<br />
R1.06<br />
MSC (c) 95-8<br />
Single <strong>Reader</strong> Interface Module with a<br />
Dorado 780 Card and Pin <strong>Reader</strong><br />
Switch Set for Mode 5<br />
ABA Card Clock &<br />
Data<br />
A<br />
B<br />
C<br />
SW1<br />
ON<br />
Black wire<br />
Brown wire<br />
Yellow wire<br />
Green wire<br />
GND<br />
BZR<br />
LED<br />
CLK/D1<br />
D<br />
White wire<br />
DAT/D0<br />
OFF<br />
Red wire<br />
80 mA maximum<br />
+12V<br />
TR+<br />
Dorado <strong>Reader</strong><br />
Model 780<br />
TR-<br />
SG<br />
GND<br />
12 VDC<br />
Power Supply<br />
revision 7 — 47