<strong>Alternative</strong> <strong>Reader</strong> <strong>Wiring</strong> <strong>Guide</strong><br />
19.3.2 <strong>Wiring</strong> the BAS-1320<br />
Dual <strong>Reader</strong> Interface Module<br />
VO<br />
READER 1<br />
LED<br />
BZR<br />
D1/CLK<br />
D0/DATA<br />
GND<br />
VO<br />
READER 2<br />
LED<br />
BZR<br />
D1/CLK<br />
D0/DATA<br />
GND<br />
TYPICAL SOFTWARE SETTINGS:<br />
1. Dipswitch 1 should be set On<br />
2. Pins 3 and 9 should be jumpered together<br />
3. <strong>Reader</strong> Type = Single Interface (Weigand/Prox)<br />
4. LED Mode = 2 Wire LED Control<br />
1 2 3 4 5 6 7 8 9<br />
ON<br />
12345678<br />
Iolan<br />
(LA-XXW-PRXKY-MX 1050 -<br />
4021 - 092)<br />