29.10.2014 Views

Alternative Reader Wiring Guide - Best Access Systems

Alternative Reader Wiring Guide - Best Access Systems

Alternative Reader Wiring Guide - Best Access Systems

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Alternative</strong> <strong>Reader</strong> <strong>Wiring</strong> <strong>Guide</strong><br />

8. Ceia <strong>Reader</strong>s<br />

8.1. Ceia Freedom <strong>Reader</strong> with Keypad (Prox)<br />

The maximum power rating on the Freedom <strong>Reader</strong> is between 5-30 VDC. The normal current draw for the<br />

reader is 40 mA. The keypad on the reader operates using a 4-bit output. This is not the standard format.<br />

This is the only format that is tested and supported by BEST. The LED functions using single wire LED<br />

control. Both the keypad and the LED meet all the requirements for functionality that BEST requires.<br />

Follow the diagrams below to wire the reader properly.<br />

8.1.1 <strong>Wiring</strong> the BAS-1300<br />

1 2 3<br />

4 5 6<br />

TYPICAL SOFTWARE SETTINGS<br />

1. <strong>Reader</strong> Type = WIEGAND/PROX<br />

2. Keypad = 4-Bit Output<br />

3. LED Mode = SINGLE WIRE LED CONTROL<br />

7 8 9<br />

*<br />

0<br />

#<br />

Single <strong>Reader</strong> Interface Module<br />

GND<br />

BZR<br />

LED<br />

CLK/D1<br />

DATA/D0<br />

VO<br />

revision 7 — 35