8. Ceia <strong>Reader</strong>s<br />
8.1. Ceia Freedom <strong>Reader</strong> with Keypad (Prox)<br />
The maximum power rating on the Freedom <strong>Reader</strong> is between 5-30 VDC. The normal current draw for the<br />
reader is 40 mA. The keypad on the reader operates using a 4-bit output. This is not the standard format.<br />
This is the only format that is tested and supported by BEST. The LED functions using single wire LED<br />
control. Both the keypad and the LED meet all the requirements for functionality that BEST requires.<br />
Follow the diagrams below to wire the reader properly.<br />
8.1.1 <strong>Wiring</strong> the BAS-1300<br />
1 2 3<br />
4 5 6<br />
TYPICAL SOFTWARE SETTINGS<br />
1. <strong>Reader</strong> Type = WIEGAND/PROX<br />
2. Keypad = 4-Bit Output<br />
3. LED Mode = SINGLE WIRE LED CONTROL<br />
7 8 9<br />
*<br />
0<br />
#<br />
Single <strong>Reader</strong> Interface Module<br />
GND<br />
BZR<br />
LED<br />
CLK/D1<br />
DATA/D0<br />
VO<br />