Chapter 7 RETAINING WALL<br />

p a = K a p 0= K a γ z (7.7)<br />

p a = K p p 0 = K p γ ζ (7.8)<br />

where<br />

p 0<br />

= Effective overburden pressure (unit length)= γh<br />

pa = Active lateral earth pressures (unit length)<br />

pp = Passive lateral earth pressures (unit length)<br />

z = Depth below the ground surface<br />

h = Depth of tension crack (clayey soil only)<br />

Z<br />

H<br />

p a =rZ tan 2 (45- Ø ) 2<br />

P p =rZ tan 2 (45+ Ø ) 2<br />

(a)<br />

Z<br />

ß<br />

ß<br />

p a =rZK o<br />

p p =rZK p<br />

K a = cosß β β <br />

β β <br />

K a = cosß β β <br />

β β <br />

K a = 1 K p<br />

Z<br />

2c tan (45°- Ø )<br />

2c tan (45+ Ø ) 2<br />

2<br />

Z<br />

p a = rZ tan 2 (45- Ø )-2c 2 tan(45°-Ø) P p = rZ tan 2 (45+ Ø )+2c 2 tan(45+Ø)<br />

2<br />

2<br />

(b)<br />

Figure 7.6 Triangular Lateral Force Distribution By Rankine Theory (a) For Granular Soil (b) For<br />

Cohesive Soil With Tension Crack Depth ‘H’ (Active Case)<br />

For non- granular (c’ <strong>–</strong> φ ‘) soils, the lateral pressures are :<br />

P a = K a γz <strong>–</strong> 2cK a (7.9)<br />

P p = K p γz + 2cK p (7.10)<br />

c = Cohesive strength of soil<br />

Theoretically, in soils with cohesion, the active earth pressure behind the wall becomes negative<br />

from the ground surface to a critical depth z where γh is less than 2c′ √ K a . This critical depth is<br />

referred to as the “tension crack.” The active earth pressure acting against the wall within the depth<br />

of the tension crack is assumed to be zero. Unless positive drainage measures are provided, water<br />

infiltration into the tension crack may result in hydrostatic pressure on the retaining structure <strong>and</strong><br />

should be full added to the lateral earth pressure.<br />