Chapter 5 INTERPRETATION OF SOIL PROPERTIES<br />

Fig. 5.22 Field K o - OCR Relationships for (a) Natural Clays <strong>and</strong> (b) Natural S<strong>and</strong><br />

In general, the value of K o has an upper bound value limited by the passive coefficient, K p . The<br />

simple Rankine value is given by:<br />

K p = tan 2 (45° + ½ ’) = (1 + sin ’)/(1 + sin ’) (5.19)<br />

When the in-situ K o reaches the passive value K p , fissures <strong>and</strong> cracks can develop within the soil<br />

mass. This can be important in sloped masses since extensive fissuring is often associated with<br />

drained strengths that are at or near the residual strength parameters (φ r ' <strong>and</strong> c r ' = 0).<br />

5.5 FLOW PROPERTIES<br />

Soils exhibit flow properties that control hydraulic conductivity (k), rates of consolidation,<br />

construction behaviour, <strong>and</strong> drainage characteristics in the ground. Field measurements for soil<br />

permeability have been discussed previously <strong>and</strong> include pumping tests with measured drawdown,<br />

slug tests, <strong>and</strong> packer methods. Laboratory methods are presented in Section 4.6.5 <strong>and</strong> include<br />

falling head <strong>and</strong> constant head types in permeameters. An indirect assessment of permeability can<br />

be made from consolidation test data. Typical permeability values for a range of different soil types<br />

are provided in Table 5.1. Results of pressure dissipation readings from piezocone <strong>and</strong> flat<br />

dilatometer <strong>and</strong> holding tests during pressuremeter testing can be used to determine permeability<br />

<strong>and</strong> the coefficient of consolidation (Jamiolkowski, et al. 1985).<br />

March 2009 5-21