CONCEPTUAL DESIGN January 9, 2009<br />

<strong>Emeryville</strong> <strong>Center</strong> <strong>of</strong> <strong>Community</strong> <strong>Life</strong><br />

In addition, this building will be designed to accommodate a future vertical expansion.<br />

Typically, the building’s columns would extend approximately 4’-0” above the ro<strong>of</strong> framing level.<br />

At the time <strong>of</strong> expansion, new column extensions would be erected, then all new ro<strong>of</strong> framing<br />

members would be erected followed by metal ro<strong>of</strong> decking and concrete fill at the same time<br />

the next levels <strong>of</strong> braced frames were being installed. Upon completion <strong>of</strong> the steel erection, fitup<br />

and bolting and welding, the perimeter light metal stud wall framing would be put in-place.<br />

Exterior metal studs would be 6” deep x 18 gage and would be spaced at 16” on center.<br />

5. Building No. 4: Below Grade Parking Structure<br />

The below grade parking structure will be one level and will be directly beneath Building No.’s 5<br />

and 6. The foot print is approximately 46,000-gsf and will be 100’ to 120’ in width by 385’ in<br />

length. The ro<strong>of</strong> framing structure <strong>of</strong> the parking structure will represent the ground floors <strong>of</strong><br />

Building No.’s 5 and 6. This framing level will consist <strong>of</strong> a 4-1/4” lightweight concrete fill on 18<br />

gage metal deck which will provide a 3 hr fire rated assembly. The framing members will<br />

consist <strong>of</strong> W18, W21 and W24 beams and girders. All framing and decking at this level will<br />

require sprayed on firepro<strong>of</strong>ing to provide either a 4 hr separation between the parking and<br />

building occupancies. For estimating purposes, 10 psf <strong>of</strong> steel framing may be used to account<br />

for the gravity beams, girders and columns and perimeter bent plate. An allowance should be<br />

carried for a secondary topping slab and waterpro<strong>of</strong> membrane at the exposed courtyard areas.<br />

The foundations consist <strong>of</strong> a perimeter basement/retaining wall, slab-on-grade and shallow<br />

spread footings. The perimeter retaining wall will be 12” and 5.5 psf <strong>of</strong> reinforcing steel may be<br />

used for estimating purposes. In addition, the perimeter walls will require continuous back<br />

drains and full height waterpro<strong>of</strong>ing and a continuous waterpro<strong>of</strong>ing strip such at the footing<br />

and wall construction joint. The continuous footing below the wall will be 3’-6” wide by 2’-6”<br />

deep and will have 4 #6 continuous bars top and bottom and #5 stirrups at 12” on center.<br />

The slab-on-grade will be 5” thick and will be placed over a vapor barrier and a 4” layer <strong>of</strong><br />

crushed based aggregate. The slab will be reinforced with #4 bars at mid depth <strong>of</strong> the slab and<br />

will be spaced at 16” on center in each direction. The slab will be constructed in a “skip bay”<br />

fashion with a minimum <strong>of</strong> 5 construction joints running across the width <strong>of</strong> the building.<br />

Additional s<strong>of</strong>t cuts or weakened plane saw cut joints will then be required at approximately 15’<br />

centers.<br />

Shallow spread footings will include interior spread footings below the building columns and a<br />

continuous strip footing below the perimeter basement wall. The typical interior spread footings<br />

can be estimated as 11’x11’x3’ deep with #9 bars at 8” on center in each direction at the bottom<br />

<strong>of</strong> the footing. The exterior footings will be placed integrally with the perimeter basement wall<br />

continuous footing and will be 6’ wide by 8’ in length. These footings will require #7 bars at 8”<br />

on center in each direction at the bottom <strong>of</strong> the footing. The stirrups from the continuous strip<br />

footings will continue through the exterior footings and increase in width to 6’.<br />

The lateral force resisting system will consist <strong>of</strong> the perimeter basement/retaining walls and 4<br />

bays <strong>of</strong> interior 14” concrete shear walls in the transverse direction and for estimating purposes,<br />

Outline Specifications- 13