CONCEPTUAL DESIGN January 9, 2009<br />

<strong>Emeryville</strong> <strong>Center</strong> <strong>of</strong> <strong>Community</strong> <strong>Life</strong><br />

ramp that runs the length <strong>of</strong> the pool deck area providing access on the backside <strong>of</strong><br />

the pool deck.<br />

ITEM<br />

ACTUAL<br />

WOMEN’S<br />

EQUIRED<br />

WOMEN’S<br />

ACTUAL<br />

MEN’S<br />

REQUIRED<br />

MEN’S<br />

SHOWERS 1 2 2 2<br />

TOILETS 2 2 1 2<br />

URINALS 0 0 2 2<br />

LAVATORIES 2 2 1 2<br />

There is one wall mounted deck shower that at the discretion <strong>of</strong> the county health<br />

department be considered as part <strong>of</strong> the minimum count for code compliance<br />

1.6 POOL MECHANICAL EQUIPMENT<br />

The pool mechanical equipment looks to be in relatively new condition. The pool<br />

water is circulated via a 15-horsepower centrifugal pump. The pool is filtered in a<br />

single tank high rate sand filter. The pool circulation pump is connected to a time<br />

clock for possible energy savings though the time clock toggles have been removed<br />

so it cannot be used. The pool water chemistry is controlled with an ORP/pH<br />

controller. The pool water chemistry is maintained with liquid chlorine (sodium<br />

hypochlorite) and liquid acid (muriatic acid). These chemicals are fed through<br />

peristaltic chemical feed pumps that are controlled by the chemical controller. The<br />

pool water is heated by three High efficiency pool heaters. These heaters are good<br />

in providing one <strong>of</strong> the best thermal efficiencies available in a swimming pool heater.<br />

These heaters are also known for having a high maintenance requirement and a<br />

relatively short life cycle.<br />

1.7 NON-CODE COMPLIANT CONDITIONS<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Deck level underwater light junction boxes<br />

Non-complaint ADA access<br />

Pool main drains<br />

Plaster finish delaminating<br />

Lack <strong>of</strong> floor inlets for a pool wider than 40-feet<br />

Pool lacks 4’-6” safety stripe rope hooks for safety rope<br />

Pool deck depth markers lack feet and inches<br />

Slide safety shut-<strong>of</strong>f<br />

1.8 MAINTENANCE ISSUES<br />

<br />

<br />

<br />

<br />

Diving board needs replacement<br />

Slide stairs need repair<br />

Pool deck finish needs to be replaced<br />

Fixed lifeguard chair is rusting and needs to be replaced<br />

Outline Specifications- 58