CONCEPTUAL DESIGN January 9, 2009<br />

<strong>Emeryville</strong> <strong>Center</strong> <strong>of</strong> <strong>Community</strong> <strong>Life</strong><br />

2. For fences, refer to landscape narrative. All actual fence heights to be finalized during<br />

later phases. All metal fence gates to have accessible panic hardware protected from<br />

outside access by perforated metal plate.<br />

3. Attic and ro<strong>of</strong> access ships type ladders to be <strong>of</strong> galvanized metal, mounted to floor<br />

and walls, with Bilco ladder-up extension poles at the top.<br />

4. Pipe bollards around utility areas to be galvanized and painted. Size and number per<br />

PG&E standards. Color to be determined.<br />

DIVISION 06000<br />

Section 06200: Finish Carpentry and Millwork<br />

1. All interior finish carpentry is to be certified wood. Finish hardwood to be selected<br />

during next phase.<br />

2. Exposed trim to be certified maple, beech or cherry or another hardwood species to be<br />

selected with transparent stain finish. Assume 3’ high plyboo or other recycled or<br />

renewable material wainscot with base, chair rail , window and door frame trim in lobby<br />

areas and at second floor multi-purpose room. Wood chair rail, base trim, window<br />

and door moldings at library, lounges<br />

3. Painted trim to be lesser species with paint finish. Assume painted wood trim around<br />

all interior door and window openings in all other class or activity rooms, except at<br />

aluminum frames.<br />

4. Exterior trellis’s are to be <strong>of</strong> Red Cedar with cast in place concrete bases. Stain finish.<br />

Section 06410: Casework<br />

1. Casework shall be “Custom” grade, flush overlay construction. W.I.C. certification is<br />

required. All solid stock lumber shall be certified.<br />

2. Panelboard construction to be formaldehyde free MDF, Medite II or equivalent.<br />

Typical finish at all but the main desks is to be plastic laminate with wood trim except<br />

as noted. Plastic laminate selections will be from Formica, Wilsonart or Nevamar.<br />

Main desks (main reception, library, gym entry) finish to be wood veneer.<br />

3. All laboratory classrooms to have specialized lab casework, complete with sinks, gas<br />

outlets, and other required features. All lab casework to have black epoxy resin<br />

countertops, sinks, and splash.<br />