CONCEPTUAL DESIGN January 9, 2009<br />

<strong>Emeryville</strong> <strong>Center</strong> <strong>of</strong> <strong>Community</strong> <strong>Life</strong><br />

STRUCTURAL DESIGN CRITERIA AND MATERIAL SPECIFICATIONS<br />

1. Design Criteria<br />

Structural design will conform to the California Building Code, 2008 Edition with the following:<br />

Live loads: Ro<strong>of</strong> (flat) 20 psf<br />

Ro<strong>of</strong> (sloped)<br />

16 psf<br />

Floors – Classrooms<br />

40 psf<br />

Floors – Offices<br />

50 psf<br />

Floors – Libraries<br />

60 psf<br />

Floors – Corridors<br />

100 psf<br />

Floors – Corridors 2 nd , 3rd flrs 80 psf<br />

Gymnasiums<br />

100 psf<br />

Terraces 100 psf<br />

Wind Analysis: Basic wind speed 70 mph<br />

Exposure<br />

B<br />

Seismic Analysis: Static lateral force procedure with Near Source Effects.<br />

2. Subgrade Preparation<br />

In general, provide a 15 mil vapor barrier over 4" rock course under the slabs on grade. Rock<br />

course shall be rolled to a smooth surface. Because the existing subgrade soils may be<br />

expansive, the site may require over-excavation <strong>of</strong> existing soil. For estimating purposes,<br />

allowances should be made for a minimum <strong>of</strong> 12"<strong>of</strong> "non-expansive" fill be placed immediately<br />

below the 4" <strong>of</strong> subgrade preparation. This will need to be verified by the future geotechnical<br />

engineer.<br />

3. Shallow Spread Footings<br />

The building structures will be constructed on shallow spread footings and they shall extend to<br />

such depth as to bear upon firm, undisturbed native soil or engineered fill. All footings shall be<br />

founded at a depth at least 18" below the lowest adjacent exterior grade and 18" below interior<br />

finished pad grade. See Section 2 above for subgrade pad explanation. Exterior footings for all<br />

buildings founded at grade will consist <strong>of</strong> continuous grade beam footings approximately 16" in<br />

width. Interior footings will consist <strong>of</strong> continuous grade beam footings approximately 18" in<br />

width and isolated spread footings. Interior and exterior grade beams will utilize approximately<br />

15 lb/ft <strong>of</strong> reinforcing. Any and all abandoned footings, utilities, etc. shall be removed prior to<br />